Usable capacity

16 TB

Shown as about 14.55 TiB in Windows/Linux

Array
8 × 4 TB
Efficiency
50.0%

RAID 10 with 8 × 4 TB

Capacity, redundancy and performance for this array
Raw capacity32 TB
Usable capacity16 TB (14.55 TiB)
Used for parity or mirroring16 TB
Storage efficiency50.0%
Fault toleranceSurvives any 1 disk failure, and up to 4 if each failure lands in a different mirror pair. Two failures in the same pair lose the array.
Hot spares0
Total disks required8
Read performanceup to ~8× single-disk reads
Write performanceup to ~4.0× single-disk writes, write penalty 2
Minimum disks for RAID 104

Performance figures are approximations for sequential work on healthy disks. Real throughput depends on the controller, the cache, the workload and whether the array is rebuilding.

Disk layout

Capacity given up to redundancy, one block per disk. Parity is spread across all disks in a real array.

  • Pair 1
  • Pair 1
  • Pair 2
  • Pair 2
  • Pair 3
  • Pair 3
  • Pair 4
  • Pair 4
D
Data
P
Parity
M
Mirror
S
Hot spare

What to watch for

Needs a GPT partition table

At 16 TB the volume is past the 2 TiB an MBR partition table can address. Use GPT when you partition it, or the usable space will stop at 2 TiB.

Rebuild time, roughly

Replacing one failed 4 TB disk takes about 11 hours at a sustained 100 MB/s. This is an estimate: a rebuild on an array that is still serving work is routinely slower, sometimes by several times.

RAID is not a backup

Redundancy protects against a disk failing. It does nothing about deletion, corruption, ransomware, theft or fire, all of which are written faithfully to every disk at once. Keep a separate copy of anything you would miss.

Recommended file system

XFS or ext4 on Linux, NTFS on Windows

Pick the default for the operating system that will mount it. Choose an intended use above for something more specific.

Compare RAID levels

The same 8 disks of 4 TB across every level they are valid for.

Usable capacity, efficiency and fault tolerance by RAID level
Level Usable Efficiency Survives
RAID 0 32 TB 100.0% None
RAID 1 4 TB 12.5% 7 disks
RAID 5 28 TB 87.5% 1 disk
RAID 6 24 TB 75.0% 2 disks
RAID 10 Selected 16 TB 50.0% 1 disk
RAID 50 24 TB 75.0% 1 disk
RAID 60 16 TB 50.0% 2 disks
RAID-Z1 28 TB 87.5% 1 disk
RAID-Z2 24 TB 75.0% 2 disks
RAID-Z3 20 TB 62.5% 3 disks

How RAID 10 works

RAID 10 is two layers. Disks are paired into mirrors, each pair holding two identical copies, and the pairs are then striped together as if each were a single fast disk. There is no parity anywhere: redundancy is simply a second copy, which is why the arithmetic is the simplest of any redundant level and the performance is the best.

usable = (n ÷ 2) × size of the smallest disk

Efficiency is 50% at every size, and the disk count must be even. The minimum is four. Note the ordering: RAID 10 is mirrors that are then striped. RAID 01 stripes first and mirrors the stripes, is less resilient, and is almost never what you want despite the similar name.

Two worked examples

Eight 4 TB disks. (8 ÷ 2) × 4 TB = 16 TB usable, reported as 14.55 TiB. Four mirror pairs striped together.

Four 16 TB disks. (4 ÷ 2) × 16 TB = 32 TB usable. Two pairs. Compare this with RAID 6 on the same four disks, which also gives 32 TB but writes far more slowly — at four disks RAID 10 is usually the better choice.

Fault tolerance is probabilistic

This is the part worth understanding properly. RAID 10 always survives one disk failure. Beyond that it depends entirely on which disks fail. In an eight-disk array of four pairs, four failures are survivable if each lands in a different pair; two are fatal if both land in the same one. So the honest statement is "one guaranteed, up to half with luck", and anyone quoting "survives half the disks" is quoting the best case as if it were the guarantee.

The counterweight is the rebuild. Replacing a failed disk means copying its partner, one disk to one disk, with no parity to compute and no need to read the rest of the array. It finishes in a fraction of the time a parity rebuild takes and puts almost no load on the other pairs, which means the dangerous degraded window is far shorter than the one that makes RAID 5 risky on large disks.

What it is for

Databases, busy virtual machine stores, mail servers, anything doing small random writes. The write penalty is 2 — one write to each half of a mirror — against 4 for RAID 5 and 6 for RAID 6, and there is no read-modify-write cycle at all. Reads come from either half of each pair, so they scale with the full disk count.

The argument against it is the one you can see in the number above: you buy twice the disks you keep. For bulk storage that is hard to justify, and parity wins. For anything latency-sensitive it usually pays for itself.